Menu

Test Requirements

Uniformly distributed Load (UDL)

  1. Serviceability tests:
    1. Deflection under load, (span/120) + p/30 where p is the maximum distance between fasteners on the support structure. (Informative for roofing, Normative for cladding), or by
    2. Permanent deformation or cracking around fastener head, or de-indexing or de-clipping of clip fastened profiles. Serviceability failure of clip fastened products may occur when a clip disengages from the central rib, but weathertightness of the lap is not affected and roof can continue to resist increased loads.
  2. Strength tests.
    Strength tests are defined as: sheet unable to resist further loads i.e. pull-off from clips, buckling, tearing or pull-through of fasteners.
(optional caption)

    Point Load

    1. Resistance to point load on the pan, or to two ribs of narrow profiles,at the weakest point.
    2. Residual deflection after imposition of serviceability load, and application of strength load
    3. Resistance to point load on a single rib at the weakest point.
    4. Residual deflection after imposition of serviceability load, and application of strength load

    Load is applied in a downwards direction through a rubber faced pad. The weakest point is generally mid span at rib/pan adjacent to underlap.

    (optional caption)
      Clause: 
      017_001_002_000_000_000_000_000_000
      Clause Number: 
      17.1.2
      /cop/testing-and-mrm-standards/metal-cladding-testing#test-requirements
      Revision Category: 
      4 - Clause Inserted
      Revision Detail: 

      New Clause