Menu

Test Report

The following information must be supplied in the report:

  1. The number of the report and the name of the client.
  2. The date and location of the test.
  3. The name of the testing officer.
  4. The test Procedure — referencing this section of the Code of Practice.
  5. Details of the material under test — Type/Profile/ Material/ thickness/ Spans.
  6. Critical dimensions, particularly crest height and spacing, are measured, recorded and compared to published profile data.
  7. Coil number of material used to run trial material.
  8. Fastener type and fixing pattern.
  9. UDL at deflection limit.
  10. Last noted load prior to UDL serviceability failure, and mode of failure.
  11. Last noted load prior to Strength failure, or maximum load reached
  12. Pass/fail for serviceability point load to pan
  13. Pass/fail for serviceability point load to rib
  14. Pass/fail for strength point load to pan
  15. Pass/fail for strength point load to rib
Clause: 
017_001_004_000_000_000_000_000_000
Clause Number: 
17.1.4
/cop/testing-and-mrm-standards/metal-cladding-testing#test-report
Revision Category: 
2 - Editing and rearrangement
Revision Detail: 

Item Added after "f"