Pull-over Values

Pull-over values for medium and high rib trapezoidal profiles must be checked against strength loads provided by testing.

Pull-over load depends on the head or washer size. For example, as 12# and 14# screw heads have approximately the same diameter, these screw sizes have the same design load value for pull-over. If the pullover load is likely to be exceeded, the options are to increase the metal thickness or use a load-spreading washer.

Clause: 
003_008_004_000_000_000_000_000_000
Clause Number: 
3.8.4
3.12.2
/cop/structure/fasteners#pull-over-values
Revision Category: 
3 - Substantial change to recommendation
Revision Detail: 

The content of this clause has been edited as part of the overall revision of Structure. The copy was revised and the tableĀ Typical Pull over values for crest fixing (serviceability failure) was removed.