Steel Cladding Wind Load Span Graphs
The performance of profiled metal cladding depends on the profile shape, thickness of the metal, the span, and the fastening type and pattern. These values can be greatly enhanced by using load spreading washers or thicker material.
All the tests from which these graphs have been derived used the 2:3 ratio of end to intermediate span and the graphs shown are for intermediate spans only. End spans must be reduced by two-thirds for these values to be assumed.
Clause:
003_011_002_000_000_000_000_000_000
Clause Number:
3.11.2
3.14.5
/cop/structure/wind-loadspan-graphs-designs-asnzs1170#steel-cladding-wind-load-span-graphs
Revision Category:
2 - Editing and rearrangement
Draft Clause:
003_014_005_000_000_000_000_000_000
- Log in to post comments