The updates published on 1 June 2024 include improvements to Gutter Support Systems and clarifying recommendations to prevent negative pressure with Ridge Vents. Substantial changes include removing wind load/span graphs for 0.70 mm aluminium.

Editing and rearrangement updates involve updating and editing images for consistency, clarifying Roof Cladding Expansion Provisions, material thickness, and amending references to the availability of AM Coatings in New Zealand. Minor edits were made for grammar, style, clarity, and consistency.

Notable revisions:

  • We removed the option of 0.70 mm Aluminium cladding from Aluminium Cladding Wind Load Span Graphs because 0.90 mm Aluminium is offered as a standard thickness.
  • Experience showed that hot-dipped galvanised gutter support brackets are not as durable as pre-painted steel products. Therefore, we added some recommendations to improve the durability of Gutter Support Systems.
  • Although not a change in recommendation, we added a statement to Ridge Vents to help prevent negative pressure in roof cavities.
  • We clarified the positioning of oversized holes and washers to aid in making Roof Cladding Expansion Provisions.

In addition to these and some minor edits and rearrangements, several images have been revised for consistency. For a detailed list of revisions, please visit v24.06 – June 2024.

Revision Detail v24.06 - 2024 - June

CategoryClause Number (prior to update)Clause (As of current publication)Details
3 - Substantial change to recommendation5.4.2.3Spouting Support Systems Clause renamed. Expanded recommendation for compatibility of spouting support systems.
3 - Substantial change to recommendation10.10.1.3Ridge Vents Added recommendation for ridge vents to be smaller than eaves vents.
0 - Clause Removed3.11.2.3Trapezoidal Five Rib Aluminium – 0.70The clause has been removed because aluminium is now offered in 0.90mm as the standard thickness.
0 - Clause Removed3.11.2.1Corrugated Aluminium – 0.70The clause has been removed because aluminium is now offered in 0.90mm as the standard thickness.
2 - Editing and rearrangement1Introduction Updated Revisions Message and rewriting for clarity. No changes in recommendations.
1 - Minor Errata1.4Acknowledgements Typo fix: tradespeople
1 - Minor Errata1.5.1Mediation Minor revisions for grammar and clarity. No change to recommendations.
1 - Minor Errata1.5.2Adjudication Minor revision for grammar, style, and clarity. No change to recommendations.
1 - Minor Errata1.5.3Arbitration and Litigation Minor punctuation fix.
2 - Editing and rearrangement2.1Definitions Added definition for Vented Ridging.
1 - Minor Errata3Structure Minor revision for style, grammar, and clarity. No change to recommendations.
1 - Minor Errata3.2Standards Minor review for style, grammar, and clarity. No change to recommendations.
1 - Minor Errata3.2.1AS/AZS 1170.2:2011 Minor revision for style, grammar and clarity. No changes to recommendations.
1 - Minor Errata3.3Performance Minor revision for style, grammar, and clarity. No changes to recommendations.
2 - Editing and rearrangement3.4.6Material Thickness Minor review for style, grammar, and clarity. Edit to clarify the use of 0.63 mm material.
1 - Minor Errata4.2Metal Corrosion Minor edit for style, grammar, and clarity. No change to recommendations.
1 - Minor Errata4.5.2Sea Spray Minor revision for style, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.6.1Assessment of Marine Environments Minor revision for style, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.6.2Environmental Guides Minor revision for style, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.8.3Graffiti Removal Minor revision for style, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.8.4Lichen Minor revison for style, layout, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.9.1Dissimilar Metals Minor revision for style, layout, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.9.4Compatibility Table Minor revision for layout, style, grammar, and clarity. No changes to recommendations.
1 - Minor Errata4.10.1Unwashed Areas Edit for style, grammar, clarity, and consistency.
1 - Minor Errata4.10.2Poultice Corrosion Minor edit for style, grammar, clarity, or consistency. No change to recommendations.
1 - Minor Errata4.10.6Capillary Action Minor edit for style, grammar, clarity, or consistency. No changes to recommendations.
1 - Minor Errata4.11Inert Catchment Minor edits for style, clarity, consistency, and grammar. No changes to recommendations.
1 - Minor Errata4.12Ponding Minor edits for grammar, style, clarity, or consistency. No changes to recommendations.
1 - Minor Errata4.13Pitting Corrosion Minor edit for grammar, clarity, consistency, and style. No changes to recommendations.
1 - Minor Errata4.14Swarf Staining and Cut Edge Corrosion Minor edits for grammar, punctuation, clarity, and consistency. No changes to recommendations.  
1 - Minor Errata4.15Clearances Minor editing for style, grammar, clarity, and consistency. No changes to recommendations.
1 - Minor Errata4.15.1Ground Clearance Minor edit for style, layout, grammar, clarity, and consistency. No changes to recommendations.
1 - Minor Errata4.15.2Site Management Minor edit for style, grammar, layout, clarity, and conistency. No changes to recommendations.
1 - Minor Errata4.16.1.1Metallic Coatings Minor edit for grammar and punctuation. No changes to recommendations.
2 - Editing and rearrangement4.16.1.6AM Coatings Removed reference to coatings weights and availability in NZ.
1 - Minor Errata4.16.3Aluminium Minor edits for grammar, style, punctuation, and consistency. No changes to recommendations.
1 - Minor Errata4.16.4Zinc Minor edit for style, grammar, and punctuation. No changes to recommendations.
1 - Minor Errata5.7Outlets and Downpipes Edits for clarity and corrected link to Inert Catchment
1 - Minor Errata7.3.2Roof Cladding Expansion Provisions Minor edit for style, grammar, consistency, or clarity.
4 - Clause Inserted19.1v24.06 – June 2024 New clause providing details of the updates published on 1 June 2024.
(optional caption)
Clause: 
019_002_000_000_000_000_000_000_000
Clause Number: 
19.2
/cop/revision-history/v2406-june-2024
Revision Category: 
4 - Clause Inserted
Revision Detail: 

New clause providing details of the updates published on 1 June 2024.