Asymmetrical Valleys

Where opposing roofs of different pitches discharge into a valley‚ an asymmetrical valley is required. As these have reduced cross-section area compared to a symmetrical valley at the same (lower) pitch, it is often necessary to increase the valley dimensions. Increasing the depth has the biggest effect on capacity. Greater depth can be gained by using 10 mm ply valley boards, standing purlins on edge, or fitting valley boards flush with the rafter. The consequences that a deeper valley will have on the capacity of the gutter it discharges into must also be considered.

A valley baffle is recommended where the difference in roof pitches exceeds 10°. Valley baffles are also helpful in wooded locations to minimise lodging of debris under the roof overhang.

 

Clause: 
005_005_006_000_000_000_000_000_000
Clause Number: 
5.5.6
/cop/roof-drainage/valleys#asymmetrical-valleys
Revision Category: 
3 - Substantial change to recommendation
Revision Detail: 

Added recommendation for valley baffles where roof pitches excced 10°.