Pan Fixing
Pan or trough fixing is commonly used for wall fixing although it is not widely used for fixing roof cladding in New Zealand. Pan fixing is common practice in Europe and offers an economical alternative to rib fixing.
Pan fixing can be used for roof as well as wall fixing provided certain fixing conditions are met:
- Light coloured roofs are limited to 12 m, thereafter with sliding washers and crest fixed.
- Dark coloured roofs are limited to 8 m, thereafter with sliding washers and crest fixed.
- If the insulation is laid close to the roof cladding, deduct 4 m of pan fixing from the above.
- If the ceiling is insulated, the roof cavity should be vented by a ridge ventilator or other permanent vents.
- Metal roofs that are not post painted should be regarded as dark coloured due to the oxidation and change in colour and surface over time.
- Translucent fibreglass sheets can be pan fixed for 8 m then crest fixed with sliding washers for 4 m, limited to a maximum of 12 m.
- Fasteners should be a minimum of 12 x 20 mm self-drilling for steel purlins and 12 x 40 mm for timber, both using a 25 mm metal and sealing washer.
- All fasteners should be driven snug tight with a torque driver or depth locator.
- Fasteners should be placed within 50 mm of the rib of the sheeting but allowing 25 mm clearance for water egress.
N.B. The pullover design values established by testing for pan fixing are more than twice those for crest fixing.
All sheets should have full bearing on all purlins that they cross to ensure a positive seal. Care should be taken to fix at right angles to the roof, and purlin flange alignment is critical if purlin creasing is to be avoided.
Corrugate and symmetrical profiles should not be pan fixed for roof cladding.
Pan fixing of roof cladding, is used in USA and Europe because of its cost and efficiency; the pullover values are increased, and it provides a much more effective shear diaphragm for cladding lengths up to 8 m.
Clause:
014_005_002_000_000_000_000_000_000
Clause Number:
14.5.2
/cop/installation/fixing#pan-fixing
Revision Category:
0 - Clause Removed
Draft Clause:
013_005_002_000_000_000_000_000_000
- Log in to post comments