Level Back Curbs
Level back curbs are the most common solution for flashing penetrations and are the easiest to fabricate and install.
They may tend to collect debris as they have little or no transverse fall, which can limit durability. However, with normal maintenance when manufactured from the same material as the roof they should achieve the durability requirements of the NZBC.
For penetrations wider than 600 mm, or those in aggressive environments or in situations where maintenance is difficult, a freer draining design such as an arrowhead or cricket is preferable.
Clause:
009_004_002_001_000_000_000_000_000
Clause Number:
9.4.2.1
/cop/penetrations/penetration-design#level-back-curbs
Revision Category:
4 - Clause Inserted
- Log in to post comments