Insulation Panel Insulation Values

The insulation thickness of a profiled roof panel varies from 30 mm to 300 mm. To achieve the same insulating value as a flat panel, a profiled roof panel needs to be thicker. The through fasteners or fixing clips are thermal bridges, but it has been shown that these are unlikely to decrease the R-value by more than 2%.

Different cores will also have different values for thermal insulation and noise attenuation, as will the details of panel joints and interfaces with other materials.

The nett insulation value of a panel must be calculated and stated by the manufacturer.

 Since we say it won't increase by more than...we can stay with the top value.

 R-values are the reciprocal of U-values. We will stick with R-value because that is the most commonly used value for roofs and walls.

Clause: 
015_005_001_006_000_000_000_000_000
Clause Number: 
15.5.1.6
/cop/other-products/warm-roofs#insulation-panel-insulation-values
Revision Category: 
4 - Clause Inserted
Revision Detail: 

Newly created clause.