Minimising Oil Canning
Good design and installation can minimise oil canning.
Materials:
- Use thicker material.
- Use low gloss paints or embossed surfaces.
- Use natural weathering materials that dull over time.
Flashings:
- Limit flashing width to 300 mm.
- Limit the joined length of fixed flashings to 12 m.
- Attach wide flashings with brackets that allow independent thermal expansion.
- Manufacture a stiffening swage into flashings that have a face width greater than 200 mm.
- Do not fix flashings to timber with a moisture content greater than 18%.
Cladding:
- Limit cladding length.
- Ensure the purlin alignment avoids convex curving.
- Inspect for flatness before installation.
- Avoid thin materials.
Clause:
012_004_004_000_000_000_000_000_000
Clause Number:
12.4.4
/cop/fitness-purpose/oil-canning#minimising-oil-canning
Draft Clause:
011_003_004_000_000_000_000_000_000
- Log in to post comments